All Aluminum Alloy Conductor(AAAC) ASTM B399

Standard: ASTM B398,B399

Capacity: 2000ton/month

Delivery Length: accord with the request

Min.Order Qty: 1km

  • Description
  • Inquiry

Application

Used as bare overhead conductor for primary and secondary distribution. Designed utilizing a high-strength aluminum alloy to achieve a high strength-to-weight ratio; affords better sag characteristics. Aluminum alloy gives AAAC aluminum conductor higher resistance to corrosion than ACSR aluminum wire stranded.

Construction

Standard 6201-T81 high strength aluminum conductors, conforming to ASTM Specification B-399, are concentric-lay-stranded, similar in construction and appearance to 1350 grade aluminum conductors. Standard 6210 alloy conductors are similar to other alloy conductors commercially known as Ardival, Aldrey or Almelec. They were developed to fill the need for an economical conductor for overhead applications requiring higher strength than that obtainable with 1350 grade aluminum conductors, but without a steel core. The DC resistance at 20 °C of the 6201-T81 conductors and of the standard ACSR of the same diameter are approximately the same. Conductors of the 6201-T81 alloys are harder and , therefore, have a greater resistance to abrasion than conductors of 1350-H19 grade aluminum.

Specification

AAAC bare conductor meets or exceeds the following ASTM specifications:

B-398 Aluminum Alloy 6201-T81 Wire for Electrical Purposes

B-399 Concentric-Lay-Stranded 6201-T81 power transmission lines

ASTM B399

Code Name Area Size & Stranding of ACSR with Equal Diameter No. & Diameter of wires Overall Diameter Weight Nominal Breaking Load
Nominal Actual
MCM mm2 AWG or MCM Al/Steel mm mm kg/km kN
Akron 30.58 15.48 6 6/1 7/1.68 5.04 42.7 4.92
Alton 48.69 24.71 4 6/1 7/2.12 6.35 68.0 7.84
Ames 77.47 39.22 2 6/1 7/2.67 8.02 108 12.45
Azusa 123.3 62.38 1/0 6/1 7/3.37 10.11 172 18.97
Anaheim 155.4 78.65 2/0 6/1 7/3.78 11.35 217 23.93
Amherst 195.7 99.22 3/0 6/1 7/4.25 12.75 273 30.18
Alliance 246.9 125.1 4/0 6/1 7/4.77 14.31 345 38.05
Butte 312.8 158.6 266.8 26/7 19/3.26 16.30 437 48.76
Canton 394.5 199.9 336.4 26/7 19/3.66 18.30 551 58.91
Cairo 465.4 235.8 397.5 26/7 19/3.98 19.88 650 69.48
Darien 559.5 283.5 477.0 26/7 19/4.36 21.79 781 83.52
Elgin 652.4 330.6 556.5 26/7 19/4.71 23.54 911 97.42
Flint 740.8 375.3 636.0 26/7 37/3.59 25.16 1035 108.21
Greely 927.2 469.8 795.0 26/7 37/4.02 28.14 1295 135.47
  1. Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 52.5% IACS, AC resistance at 60Hz
  2. Current ratings are based on 75°C conductor temperature, 25°ambient,2ft/s wind, 96/watts/sq.foot sun,.05 coefficients of emissivity and absorption.